What is the Novec 1230 replacement? Meet PAF-222 FK-5-1-12, a clean agent fire suppressant for data centers, server rooms, and electrical rooms

Novec-1230 fire suppression agent

Among clean agent fire suppression systems, Novec 1230 has been one of the most popular agents, particularly in areas holding electronic equipment and critical assets: data centers, server rooms, electrical control rooms and communication rooms.

Many operators are now looking for a Novec 1230 replacement, driven by changes in production, supply and environmental regulation.

One alternative worth a look is PAF-222 FK-5-1-12, a clean agent for fire suppression systems that puts fires out without leaving residue behind, and suits protecting high value assets.

Why look for a Novec 1230 replacement?

On 20 December 2022, 3M announced plans to phase out all PFAS manufacturing by the end of 2025, fluorinated fluids in its product portfolio included. 3M later stated that it had exited the PFAS manufacturing business by the end of 2025.

That leaves anyone running a Novec 1230 system with several things to think about:

  • Refilling the agent, or maintaining the system, in future

  • Continuity of agent supply

  • Changing the manufacturer or brand of the agent

  • Compatibility with the existing system

  • Standards and certifications for the agent and equipment

  • Where environmental regulation is heading

  • Total lifecycle cost of the system

What is PAF-222?

PAF-222 is an FK-5-1-12 clean agent designed for clean agent fire suppression systems, aimed at protecting areas holding critical equipment and assets.

FK-5-1-12 is well known across the clean agent industry, and 3M's Novec 1230 is another trade name for an agent in the FK-5-1-12 group.

For product detail, see What is PAF-222. For the technical name of the agent, see What is FK5112 / What is FK-5-1-12. For the chemical name as it appears on SDS documents, see What is Perfluorohexanone

Can PAF-222 replace Novec 1230?

It can be considered as a replacement. Clean agent systems are designed around a number of factors:

  • Design concentration

  • Room volume

  • Quantity of agent

  • Storage pressure

  • Cylinder size and quantity

  • Piping size

  • Length of the piping system

  • Nozzle size and location

  • Discharge time

  • Detection and control system

So if you want to move from Novec 1230 to PAF-222, an engineer or specialist should inspect and redesign the system against the technical data for the agent and equipment you choose.

To compare the types of clean agent system before designing a new one, read more at Different types of clean agent fire suppression systems and Clean agent fire suppression systems

Comparing Novec 1230 and PAF-222

Topic

Novec 1230

PAF-222 (FK-5-1-12)

Type

Clean Agent

Clean Agent

Main Agent

FK-5-1-12

FK-5-1-12

ODP

0

0

GWP

<1

<1

Suitable for electronic equipment

Data Center

Server Room

Electrical Room

Leaves residue like dry chemical powder

No residue

No residue

Key Issue

3M brand phased out production

Current and future alternative

What PAF-222 offers as a Novec 1230 replacement

1. It is a clean agent

PAF-222 can be used in systems that have to protect critical equipment and assets, and it leaves no agent residue behind once it has done its work.

That suits areas such as:

  • Data centers

  • Server rooms

  • Control rooms

  • Electrical rooms

  • UPS rooms

  • Communication rooms

  • Industrial control rooms

  • Electronic equipment storage rooms

  • Military areas and mission critical systems

2. No damage from agent residue

Unlike dry chemical powder or foam, which can take time and money to clean up after an incident.

Clean agents such as PAF-222 are designed for areas holding critical equipment, where the system has to be back in service quickly.

3. Suits protecting electronic equipment

In a data center or server room, damage from water, dry chemical powder or residue can cost more than the fire itself.

Choosing a clean agent system is one way to cut the risk to sensitive equipment.

4. Works as a transition path from Novec 1230

If you already run Novec 1230, moving to an FK-5-1-12 agent such as PAF-222 is one route to planning the continued use of a clean agent system.

Check the details of your existing system before changing agent, every time.

Who is PAF-222 for?

PAF-222 suits organizations that want a fire suppression system to do two jobs at once: protect against fire, and preserve critical assets.

Data center

Protects servers, network equipment, storage and the IT systems the business runs on.

Electrical room

Suits areas holding electrical cabinets, switchgear, control panels and critical electrical equipment.

UPS room

Protects areas holding backup power systems and the electrical equipment operations depend on.

Control room

Suits control rooms and automatic control systems that cannot afford long periods of downtime.

Telecommunication systems

Protects network equipment and communication systems that have to run continuously.

Security and defense agencies

Suits areas holding electronic systems, communication systems and mission critical equipment that need fire protection with minimal impact on the equipment.

For guidance on choosing cylinders and systems specifically for data centers, server rooms and electrical rooms, read more at Fire extinguishers for Data Centers / Server Rooms / Electrical Rooms

So when should you switch from Novec 1230 to PAF-222?

If you still run a Novec 1230 system, plan ahead, particularly when you need to:

Refill agent → repair the system → expand the system → change cylinders → retrofit the system → install a new system

Before deciding to change agent, check at least five things.

1. Check the existing agent

Confirm that it is FK-5-1-12.

2. Check the piping

The existing pipework may need inspecting and recalculating against the properties of the agent you intend to use.

3. Check cylinders and pressure

Check that the containers and related equipment are suitable.

4. Check nozzles

Nozzle size and position.

5. Check standards and certifications

Choose agents and equipment with technical documentation and certification that meet the project requirements. For the certification documents to request and check before purchasing, see What are the certification standards of PAF-222

PAF-222 and the future of clean agent fire suppression

Change across the industry is pushing building owners and system managers to look further than "will it put the fire out."

A modern fire suppression system has to answer for:

Safety → asset protection → business continuity → environment → sustainability of supply

Which puts PAF-222 among the options for organizations planning a Novec 1230 replacement, or looking for a clean agent system on a new project.

What to read next after understanding Novec 1230 replacements

Now that you know what a Novec 1230 replacement is, and how PAF-222 FK-5-1-12 works as an alternative, these related topics follow on:

Frequently Asked Questions (FAQ)

1. What is a Novec 1230 replacement?

A clean agent that can be used in clean agent systems to protect critical areas such as data centers, server rooms and electrical rooms. One route is to choose a product using FK-5-1-12 from another manufacturer, PAF-222 for instance.

2. Can PAF-222 be used instead of Novec 1230?

PAF-222 FK-5-1-12 can be considered as an option for transitioning away from Novec 1230 products.

3. What is the difference between PAF-222 and Novec 1230?

Novec 1230 is 3M's trade name for the FK-5-1-12 agent. PAF-222 is PAF GLOBAL's trade name for a product using the same agent.

4. Is PAF-222 suitable for data centers?

It suits designing clean agent systems for data centers and server rooms, since it is an agent built for areas holding critical equipment where damage from residue has to be kept down.

5. Does PAF-222 leave residue after extinguishing?

Clean agents such as FK-5-1-12 do not leave residue the way dry chemical powder does, which suits areas holding electronic equipment and critical assets.

6. Why look for a Novec 1230 replacement?

Because 3M announced the phase-out of PFAS-related substances by the end of 2025 and has stated it exited the PFAS manufacturing business, so users have to think about supply and long term use. If your existing system runs HFC-227ea or FM-200, read the transition guidelines at What is the HFC-227ea replacement.

7. Can PAF-222 be filled directly into an existing Novec 1230 system?

Check first. Even though both agents sit in the FK-5-1-12 group, the system should be inspected and redesigned around agent quantity, pressure, piping, nozzles and the product specifications.

8. Is PAF-222 suitable for electrical rooms?

It can be used to design clean agent systems for electrical rooms and areas holding electrical equipment, weighing the risk types, the characteristics of the room, and the system specifications.

9. Can PAF-222 be used instead of FM-200?

PAF-222 and FM-200 are different agents. Moving from FM-200 to PAF-222 means recalculating and redesigning the system. The original agent volume and design parameters should not be carried over directly.

10. What type of fire suppression system does PAF-222 suit?

Clean agent fire suppression systems, particularly enclosed spaces where the agent concentration can be controlled: data centers, server rooms, control rooms and electrical rooms.