Data Center HTKD-CFXS-01 Cabinet Type – Fire Suppression System
The HTKD-CFXS-01 cassette-type fire suppression system cabinet operates using an automatic fire extinguishing control system with PAF-222 Clean Agent [FK-5-1-12]. It features an LCD display screen and a main control unit, consisting of the cassette-type fire suppression cabinet, fire extinguishing equipment, power supply, and other optional modules. It supports communication and remote control, fire alarm systems, multi-channel control output ports, and other comprehensive functions.
Details and features
All-in-One Structure: Fully equipped with firefighting equipment inside the unit. There is no need to install additional external fire extinguishers, allowing for convenient, fast installation and space-saving.
LCD Display: Clearly and accurately displays alert information, system errors, and various settings.
Multiple Operating Modes: Supports manual, automatic, emergency start, and SMS remote control operation, allowing you to select the appropriate operating mode to suit your environment needs.
Automatic Alarm and Fire Extinguishing System: Real-time fire notification and remote signaling, along with an automatic smoke detection system to monitor fires inside the control cabinet in real-time, instantly triggering automatic fire suppression.
Size / Model Details
Coverage Area: 1.5 square meters
Delay Time: Adjustable 0 ~ 60 seconds
Maximum Current: 2A
Main Power System: AC220 / 3A Protection Fuse
Backup Power System: DC24V 3.3A
Operating Temperature: -20°C ~ 50°C
SIM Card Support: MICRO-SIM
Alarm Signal: Smoke detection and Temperature detection
Dimensions: 482mm × 390mm × 89mm
What is the HTKD-CFXS-01 Cassette-type Fire Suppression System?
The HTKD-CFXS-01 Cassette-type Fire Suppression System is a clean agent fire suppression system specifically designed for areas housing electrical and electronic equipment. The system detects and discharges the extinguishing agent directly into high-risk spots, making it ideal for enclosed or semi-enclosed spaces such as electrical enclosures, control panels (racks), small server rooms, or specific localized protection areas within a Data Center.
This system utilizes PAF-222 Clean Agent [FK-5-1-12], which leaves no residue or mess after discharge compared to dry chemical powder extinguishers. Therefore, it is highly suitable for areas containing critical equipment where minimizing post-incident equipment damage is essential.
What applications are suitable for the HTKD-CFXS-01 Cassette-type Fire Suppression System?
This type of system is ideal for areas requiring localized protection rather than total flooding of the entire room, particularly spots with electrical equipment, control units, or continuously operating devices.
Application Areas | Why it is suitable |
Data Center | Used to supplement localized protection inside racks, cabinets, or critical equipment zones. |
Server Room | Ideal for areas with IT equipment where chemical powder residue must be avoided. |
Electrical Enclosure / MDB Cabinet | Perfect for enclosed spaces facing high risks from heat accumulation or electrical short circuits. |
Control Panel | Suitable for electrical control panels, machinery, or automated control systems. |
Key Features of the HTKD-CFXS-01 Cassette-type Fire Suppression System
The HTKD-CFXS-01 Cassette-type Fire Suppression System is ideal for applications requiring localized, rapid-response fire suppression, especially in areas with space constraints that make large-scale system installations difficult.
Key highlights to consider:
A clean agent fire suppression system for electrical equipment areas; non-conductive.
Uses PAF-222 Clean Agent [FK-5-1-12].
Suitable for Data Centers, Server Rooms, electrical cabinets, and Control Panels.
Detects and suppresses fire directly at the source (Direct Suppression).
Uses clean agent; leaves no residue like dry chemical powder.
Easy to install and maintain.
Operates continuously 24/7.
Why is this system ideal for Data Centers and Server Rooms?
Data Centers and Server Rooms consolidate high-value electrical and electronic equipment such as servers, racks, UPS, switches, routers, storage, and various control systems. In the event of a fire, damage is caused not only by flames but also by soot, heat accumulation, and system downtime.
This system perfectly addresses localized protection because it can be installed directly inside high-risk areas, such as electrical cabinets, racks, or certain types of enclosures. This allows the clean agent to discharge rapidly into the source of the fire.
However, for large Data Centers or Server Rooms, relying solely on localized protection is not recommended. It should be evaluated in conjunction with alarm systems, PAF-222 (MJZ Series) clean agent fire extinguishers, and permanent piped fire suppression systems to design a protective system suitable for the actual site conditions.
How does the HTKD-CFXS-01 Cassette-type Fire Suppression System differ from PAF-222 (MJZ Series) Clean Agent Fire Extinguishers?
The HTKD-CFXS-01 Cassette-type Fire Suppression System and the PAF-222 (MJZ Series) Clean Agent Fire Extinguisher have different roles and operating methods. They can be used together to achieve maximum safety in the same area as follows:
Type | Application Method | Suitable For |
HTKD-CFXS-01 Cassette-type Fire Suppression System | Localized fire suppression system that automatically detects and discharges clean agent in high-risk zones. | Electrical cabinets, racks, control panels, server cabinets. |
PAF-222 (MJZ Series) Clean Agent Fire Extinguisher | Portable fire extinguisher (Manual). Requires a user to respond to the incident and manually discharge the agent. | General areas, server rooms, electrical rooms, offices. |
Automatic Temperature Sensing Clean Agent Extinguisher (PZGW Series) | Automatic localized fire extinguishing device (activates when heat reaches a specified temperature). | Electrical cabinets, MDB cabinets, control panels. |
Permanent Piped Fire Suppression System | Fixed installation fire suppression system designed for total flooding of an entire room or zone with clean agent. | Data Centers, server rooms, large electrical rooms. |
Note: For areas with both room-level and localized risks, consider utilizing multiple systems together.
What to check before installing the system
Gathering clear spatial and equipment information helps the team evaluate the most suitable model and installation pattern.
Key information to check and prepare:
Type of Space: such as Data Center, Server Room, electrical cabinet, or Control Panel.
Layout or actual photos of the site, electrical equipment placement, and high-risk points.
Equipment placement constraints.
Related Articles and Pages
For further study before purchasing or designing a system, please refer to the following related pages:
Read more: What is PAF-222?
View product category: Clean Agent Fire Extinguishers
Compare systems: Permanent Piped Fire Suppression Systems
Localized automatic systems: Automatic Temperature Sensing Clean Agent Extinguishers (PZGW Series)
Compare with portable models: PAF-222 Clean Agent Fire Extinguishers (MJZ Series)
Choose by application: Fire Extinguishers for Data Centers / Server Rooms / Electrical Rooms
Request pricing and documents: Contact for a Quote
Frequently Asked Questions (FAQ)
What is the HTKD-CFXS-01 Cassette-type Fire Suppression System?
The HTKD-CFXS-01 Cassette-type Fire Suppression System is a clean agent system specifically designed for areas housing electrical and electronic equipment. It detects and suppresses localized incidents quickly, making it ideal for small enclosed spaces such as electrical cabinets, control panels, and server cabinets.
Is this system suitable for Data Centers or Server Rooms?
It is ideal for localized protection within Data Centers or Server Rooms, such as installation inside racks, cabinets, or critical control enclosures. However, risk assessments should be made to integrate it with other fire suppression systems.
How does the HTKD-CFXS-01 Cassette-type Fire Suppression System differ from PAF-222 (MJZ Series) Clean Agent Fire Extinguishers?
HTKD-CFXS-01 Cassette-type Fire Suppression System: A fixed system that automatically detects and discharges clean agent to suppress fire immediately.
PAF-222 (MJZ Series) Clean Agent Fire Extinguisher: A portable (manual) device requiring personnel to assess the situation and manually discharge the agent to extinguish the fire.
What documents should I request prior to installation?
You should request SDS, Datasheets, Drawings, Certificates, product model details, installation layouts, and quotes for review by engineers, maintenance, or safety officers before making a decision.